IntroductionThis document was prepared to aid the technician in troubleshooting the possible causes of Alarm 12 (AL-12) on an S or P Series Spindle Amplifier. Alarm 12 is generated when the spindle control area has sensed an abnormal amount of current flowing in the DC link portion of the spindle. There are several reasons why this condition could occur, the following procedure will attempt to narrow down the culprit fault area.SetupThe manual ' S Series/P Series', GFZ-65015E, is being used as a guide for troubleshooting this alarm.
GE Fanuc Automation makes no representation or warranty, expressed, implied, or statutory with respect to, and assumes no responsibility for the accuracy, completeness, sufficiency, or usefulness of the information contained herein.
It would be useful if the technician could have this manual present while performing the steps outlined in this document.Section 4 of the manual, entitled 'TROUBLESHOOTING', contains a brief description of each fault indicated in the display of the spindle drive as well as some general details of the (including Alarm 12). In section 6, entitled 'REPLACING FUSE AND PCB', you will find the procedure for the removal and troubleshooting of the PCB and Transistor modules.
Removal of PCB is necessary to be able to see and troubleshoot the transistor modules, diode block, regenerative resistor and other components.ProcedureBefore starting, please take time to note the conditions that may have contributed to this alarm: When id it occur, has it happened before, have you reset the drive repeatedly, does it occur during a cut, etc. Also, note the part numbers of your spindle amplifier and your spindle motor. These numbers will be necessary when and are also needed to determine the specific you may need to remedy the fault.
The part number of the spindle amplifier can be found on a sticker somewhere on the frame of the amplifier and will have the form A06B-6059-Hxxx(#Hyyy).
CodesError000Re-apply the power after the parameter has been input001TH Alarm (A character with incorrect parity was input) Correct the tape002TV Alarm (The number of characters in a block is odd). This alarm will be generated only when the TV check is effective003Data exceeding the maximum allowable number of digits was input004A numeral or the sign (-) was input without an address at the beginning of the block005The address was not followed by the appropriate data but was followed by another address of EOB code006Sign “-” input error (sign “-” was input after a address with which it can’t be used. Or two “-” signs were used).007Decimal Point “.” Input error (A decimal point was input after a address with which it can’t be used. Or two decimal points were input).008The switch position of the tape reader was not AUTO (without reel) or REEL ON/REEL OFF (with reels).009Unusable character was input.
Kampung anime one piece. Situs Nonton Online (Streaming) dan Download Anime Subtitle Indonesia, juga menyediakan Batch Download (BD) dengan pilihan berbagai format dan kualitas yang tersedia (240-360 SD-480p HD-720p FHD-1080p QHD-1440p, mp4 mkv 3gp). Nonton Online (Streaming) dan Download Anime One Piece Subtitle Indonesia. One Piece Sub IndoBercerita tetang seorang laki-laki bernama Monkey D. Luffy,yang menentang arti dari gelar bajak laut. Daripada kesan nama besar, kejahatan, kekerasan, dia.
(E).010A unusable G code was commanded.